Windows XP Home And Professional X86 (32-bit) Free Download Disc Image ISO Files - GetMyOS
Sunday, October 20, 2019
Sunday, September 29, 2019
Access to systems
Homelab SSH Tunnel
ssh -L 3389:192.168.4.23:3389 -p 2233 cdave@83.208.153.96
Putty config - https://blog.devolutions.net/2017/4/how-to-configure-an-ssh-tunnel-on-putty
FlexBook Production
ssh cdave@95.80.241.19 -p 2222
ssh -L 3389:192.168.4.23:3389 -p 2233 cdave@83.208.153.96
Putty config - https://blog.devolutions.net/2017/4/how-to-configure-an-ssh-tunnel-on-putty
FlexBook Production
ssh cdave@95.80.241.19 -p 2222
Tuesday, June 11, 2019
Kubernetes Training
Lab
https://github.com/azurecz/java-k8s-workshop/
Key Vault
Safeguard cryptographic keys and other secrets used by cloud apps and services
https://azure.microsoft.com/en-in/services/key-vault/
https://github.com/azurecz/java-k8s-workshop/
Key Vault
Safeguard cryptographic keys and other secrets used by cloud apps and services
https://azure.microsoft.com/en-in/services/key-vault/
Thursday, May 2, 2019
PSC Convergence from External to Embedded mode & Network Ports
TCP/UDP 389
TCP/UDP 636
TCP 443
TCP 2012
TCP 2014
TCP 2015
TCP/UDP 2020
TCP 5480
TCP 8281
TCP/UDP 902
Tuesday, April 9, 2019
vMotion and Virtual Switches
vMotion vSwitche N-VDS VDS VSS
---------------- BUG DESCRIPTION: ---------------- Live migration of a VM from one NVDS to another NVDS was failing and Powering off the VM. ----------- ROOT CAUSE: ----------- VC thinks LS with same network name across datacenter to be different networks and send a deviceBackingChange in the migrateSpec even if the vMotion is over same LS. ------- OUTPUT: ------- 1). Live migration of a VM from NVDS to same NVDS within same Datacenter and across Datacenters is now PASSING. 2). Live migration of a VM from one NVDS to another NVDS within same Datacenter and across Datacenters is now BLOCKING. 3). Live migration of a VM from VSS to NVDS and vice-versa within same Datacenter and across Datacenters is now PASSING. ----------------------------- BUILDS USED FOR VERIFICATION: ----------------------------- VC: 12713247 (vSphere67u2) ESXi: 12698103 (vSphere67u2) ------------------ SCENARIOS COVERED: ------------------ (1). Live migration of VM across VSS, DVS and NVDS(OPN) both in single and across VC/Datacenters. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Network-Path Same-DC Across-DC XVC (Across VC) ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ VSS1 -> VSS1 (different PG) PASS(E1) NA NA VSS1 -> VSS2 (within same host) PASS(E1) NA NA VSS1 -> VSS2 (with different configs) PASS PASS PASS VSS1 -> VSS2 PASS PASS PASS DVS1 -> DVS1 (same port group) PASS NA NA DVS1 -> DVS1 (different port group) PASS NA NA DVS1 -> DVS2 (with different configs) PASS PASS PASS DVS1 -> DVS2 PASS PASS PASS OPN1 -> OPN1 PASS PASS PASS OPN1 -> OPN2 PASS(B1) PASS(B1) PASS(B1) DVS -> VSS PASS(B1) PASS(B1) PASS(B1) VSS -> DVS PASS PASS PASS VSS -> OPN PASS PASS PASS OPN -> VSS PASS PASS PASS DVS -> OPN PASS PASS PASS OPN -> DVS PASS PASS PASS VSS, DVS, OPN -> OPN, DVS, VSS PASS PASS PASS VSS, DVS, OPN -> OPN, OPN, DVS PASS PASS PASS VSS, DVS, OPN -> VSS, OPN, DVS PASS PASS PASS VSS, DVS, OPN -> OPN, OPN, OPN PASS PASS PASS VSS, DVS, OPN -> VSS, OPN, OPN PASS PASS PASS VSS, DVS, OPN -> OPN, DVS, OPN PASS PASS PASS VSS, DVS, OPN -> DVS, DVS, OPN PASS PASS PASS VSS, DVS, OPN -> DVS, OPN, OPN PASS PASS PASS VSS, DVS, OPN -> VSS, OPN, VSS PASS PASS PASS VSS, DVS, OPN -> OPN, DVS, DVS PASS PASS PASS VSS, DVS, OPN -> DVS, OPN, VSS PASS PASS PASS VSS, DVS, OPN -> OPN, OPN, VSS PASS PASS PASS VSS, DVS, OPN -> DVS, OPN, DVS PASS PASS PASS With Disconnected Network Adapter PASS PASS PASS Different NVDS with Same Name PASS PASS PASS ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ E1 -> Error stack: Migrating VM standalone-cbd6dd057-esx.2-vm.0 to different network without changing its host is not supported. Please use Reconfigure API to change VM's network. B1 -> "Currently connected network interface" 'Network adapter 1' cannot use network 'LogicalNetwork2 (nsx.LogicalSwitch:00021250-382c-995d-2ae4-56c5c6fbe603)', because "the type of the destination network is not supported for vMotion based on the source network type". See KB article 56991 for more details. (2). Compatibility checks for scenarios where destination switch is without PNIC. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Network-Path Same-DC XVC (Across VC) ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ VSS1 -> VSS2 (without pnics) BLOCK(CE) BLOCK(CE) VSS1 (without pnics) -> VSS2 PASS PASS VSS -> DVS (without pnics) BLOCK(CE) BLOCK(CE) VSS (without pnics) -> DVS PASS PASS DVS1 -> DVS2 (without pnics) BLOCK(CE) BLOCK(CE) DVS1 (without pnics) -> DVS2 PASS PASS OPN -> VSS (without pnics) BLOCK(CE) BLOCK(CE) VSS (without pnics) -> OPN PASS PASS OPN -> DVS (without pnics) (NE) (NE) DVS (without pnics) -> OPN PASS PASS ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Compatibility Error (CE) -> Currently connected network interface 'device' uses network 'network', which is a 'virtual intranet'. Not Expected (NE) -> Allowing migration without CE. Raised Bug – 2289453 (3). Destination network not accessible cases. Delete the destination network before migration process starts. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Network-Path Result ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ VSS -> DVS PASS(E1) OPN -> VSS PASS(E1) OPN -> DVS PASS(E1) VSS -> OPN PASS(E2) DVS -> OPN PASS(E2) ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Task Error (E1) - "currently connected network interface 'device' uses network 'network', which is not accessible." Task Error (E2) - "A general system error occurred: Invalid fault" (4). Suspended VM migration cases. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Network-Path Same-DC XVC (Across VC) ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ VSS -> DVS PASS PASS VSS -> OPN PASS PASS DVS -> OPN PASS PASS OPN -> DVS PASS PASS OPN -> VSS PASS PASS DVS -> VSS (CW) (CW) OPN1 -> OPN2 PASS PASS VSS1 -> VSS2 PASS PASS DVS1 -> DVS2 PASS PASS ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Compatibility Warning (CW) -> Network interface" 'Network adapter 1' cannot use network 'VM Network', because "the type of the destination network is not supported for vMotion based on the source network type.
Datastore capacity expansion issue
TAM recommended to create new additional 4TB datastore, format it to VMFS 6 and use storage migration from old datastore (ibm103-xx) to new datastore (ibm104-xx).
Old datastore (ibm103-xx) will be empty and next week we will do further troubleshooting of old datastore (ibm103-xx) and will try datastore expansion in Host Client (HTML5).
TROUBLE SHOOTING COMMANDS
Checking VMFS Metadata Consistency with VOMA - https://docs.vmware.com/en/VMware-vSphere/6.5/com.vmware.vsphere.storage.doc/GUID-6F991DB5-9AF0-4F9F-809C-B82D3EED7DAF.html
voma -m vmfs -f check -d /vmfs/devices/disks/naa.00000000000000000000000000000703:3
Running the esxcli storage core device list command shows the size of the extended LUN.
Running the vmkfstools -Ph /vmfs/volumes<datastore name> command shows the original size of datastore
Running the vmkfstools -Ph /vmfs/volumes<datastore name> command shows the original size of datastore
Command partedUtil - Using the partedUtil command line utility on ESXi and ESX (1036609) - https://kb.vmware.com/kb/1036609
The whole runbook procedure is describe in VMware KB: Growing a local datastore from the command line in vSphere ESXi (2002461) - https://kb.vmware.com/kb/2002461
Wednesday, February 27, 2019
APD - ExtendAPDCondition
Good To Know about this advanced setting.
[root@esx24:~] esxcli system settings advanced list -o /Scsi/ExtendAPDCondition
Path: /Scsi/ExtendAPDCondition
Type: integer
Int Value: 0
Default Int Value: 0
Min Value: 0
Max Value: 1
String Value:
Default String Value:
Valid Characters:
Description: Trigger APD condition when paths are in unavailable states
[root@esx24:~] esxcli system settings advanced list -o /Scsi/ExtendAPDCondition
Path: /Scsi/ExtendAPDCondition
Type: integer
Int Value: 0
Default Int Value: 0
Min Value: 0
Max Value: 1
String Value:
Default String Value:
Valid Characters:
Description: Trigger APD condition when paths are in unavailable states