On the host side, you should always use an MTU of 9000 for jumbo frames and not try to match the 9216 value you're seeing on your switch. On the other hand, you see 9216 on a network switch because it's allowing overhead of different encapsulations.
Monday, April 6, 2020
ESXi NIC driver update procedure - esxcli
List NIC adapters ...
esxcli network nic list
[root@esx21:~] esxcli network nic list
Name PCI Device Driver Admin Status Link Status Speed Duplex MAC Address MTU Description
------ ------------ ------ ------------ ----------- ----- ------ ----------------- ---- -------------------------------------------------------
vmnic0 0000:01:00.0 ntg3 Up Up 1000 Full 90:b1:1c:13:fc:14 9000 Broadcom Corporation NetXtreme BCM5720 Gigabit Ethernet
vmnic1 0000:01:00.1 ntg3 Up Up 1000 Full 90:b1:1c:13:fc:15 9000 Broadcom Corporation NetXtreme BCM5720 Gigabit Ethernet
vmnic2 0000:02:00.0 ntg3 Up Down 0 Half 90:b1:1c:13:fc:16 1500 Broadcom Corporation NetXtreme BCM5720 Gigabit Ethernet
vmnic3 0000:02:00.1 ntg3 Up Down 0 Half 90:b1:1c:13:fc:17 1500 Broadcom Corporation NetXtreme BCM5720 Gigabit Ethernet
List of drivers
esxcli software vib list | grep ntg3
[root@esx21:~] esxcli software vib list | grep ntg3
ntg3 4.1.3.2-1vmw.670.1.28.10302608 VMW VMwareCertified 2018-12-15
Driver details
vmkload_mod -s ntg3
[root@esx21:~] vmkload_mod -s ntg3
vmkload_mod module information
input file: /usr/lib/vmware/vmkmod/ntg3
Version: 4.1.3.2-1vmw.670.1.28.10302608
Build Type: release
License: BSD
Required name-spaces:
com.vmware.vmkapi#v2_5_0_0
Parameters:
initRingSzRxJmb: ushort
RX Jumbo Ring Size
initRingSzRxStd: ushort
RX Standard Ring Size
intrMode: ushort
Interrupt mode: 0=IntX, 1=MSI(Default)
Update driver version
esxcli software vib update -d. file.vib
Reboot server
Friday, March 27, 2020
vCenter http request rate
PR: https://bugzilla.eng.vmware.com/show_bug.cgi?id=2088939
Resil jsem dneska limitaci vCentra pro spousteni API (ansible/powercli) prikazu. Reseni je relativne jednoduche - navysit v souboru: /etc/vmware-vapi/endpoint.properties hodnotu http.request.rate.count=360 na treba 1000 a restartovat vmware-vapi-endpoint sluzbu
Number of vCenter API requests
Pocet API volani do vCentra
Resil jsem dneska limitaci vCentra pro spousteni API (ansible/powercli) prikazu. Reseni je relativne jednoduche - navysit v souboru: /etc/vmware-vapi/endpoint.properties hodnotu http.request.rate.count=360 na treba 1000 a restartovat vmware-vapi-endpoint sluzbu
Number of vCenter API requests
Pocet API volani do vCentra
Wednesday, March 25, 2020
vLCM versus VxRAIL
Q: with the introduction of vLCM with readynodes, what would the value out of selling VxRail ?
A: Though vLCM provides firmware support, it doesn’t provide pre-validated and pre-integrated bundles, which VxRail does. Our customers have told us that this is a big pain point. VxRail images are getting customer from one valid image/driver/firmware state to another valid state.
VxRail provides other value such as enhanced phone home support and additional automation such as auto-buildout of clusters.
A: Though vLCM provides firmware support, it doesn’t provide pre-validated and pre-integrated bundles, which VxRail does. Our customers have told us that this is a big pain point. VxRail images are getting customer from one valid image/driver/firmware state to another valid state.
VxRail provides other value such as enhanced phone home support and additional automation such as auto-buildout of clusters.
Sunday, March 22, 2020
vSAN/DRS awareness to be introduced in vSAN/vSphere 7.0! (NOT RELEASE in 7.0)
Originally piblished here ...
It was briefly mentioned here, but I figured I would elaborate on this new cool feature for vSAN Stretched Clusters which is DRS Awareness of vSAN Stretched Clusters. So what does this mean? Well, it is fairly straight forward. DRS will take vSAN resync traffic into consideration when the DRS algorithm runs. I can probably explain best by talking through a scenario:
- vSAN Stretched Cluster environment with 4 hosts and a witness
- VMs running in Preferred and in Secondary
- VMs configured with "should rules" to stay within their fault domain
- ISL between "data locations" is impacted
- HA has restarted the VMs of the secondary site in the preferred site
- ISL is now restored
What would happen without DRS awareness of vSAN stretched clusters is that DRS would automatically migrate VMs back to the Secondary site as soon as it becomes available. DRS runs every minute in vSphere 7.0 so it is very likely that vSAN is still resyncing data. The problem with this is two-fold:
- The vMotion process will slow down the resync of data temporarily
- Blocks which have not been resynced and are being read by the VM will need to be fetched from the remote location
As you can imagine this is an undesired situation. As such in vSphere / vSAN 7.0 a whole new level of integration is introduced between DRS and vSAN. Now DRS will be aware of what is happening on the vSAN layer. If vSAN is syncing a particular component of a virtual machine, then DRS will not move the VM back! It will wait until the resync has completed and then move the VM back. This ensures that the migration won't conflict with the resync, and of course that when the VM is migrated that it will have "site read locality".
It is a feature our team had been asking for and which was tested within VMware Cloud on AWS, and I am happy to see it made it into the "regular" vSphere release.
Friday, February 21, 2020
vSphere Support for Intel Optane Persistent Memory
VMware and Intel are working closely to develop the market and use-cases for Intel’s Optane Persistent Memory (PMEM).
This technology is available in two modes:
- App-direct mode (AD in short, also known as Persistent Memory): vSphere 6.7 U3 enables Intel®Optane™ DC Persistent Memory in “App-Direct” mode. You can take advantage of the large capacity, affordability and persistence benefits offered in this mode and deploy in production any supported 3rd party application without any restriction with full VMware support. VMware encourages its customers to leverage this technology in “App-Direct” mode. For more information on the App-Direct mode performance benefits in virtualization environment, please refer to PMEM App-Direct WP.
- Memory-Mode (MM): vSphere 6.7 Update 3 enable Intel® Optane™ DC Persistent Memory in“Memory” mode. vSphere usage of Intel® Optane™ DC Persistent Memory in “Memory mode”can offer increased memory capacity and TCO improvements for relevant workloads. Initially, VMware will support “Memory” mode for appropriate use-cases in production deployments (refer toPMEM memory-mode WP); such a deployment should go through RPQ process to secure VMware support.
Specific vSphere and VSAN support statement for this technology is available in this KB articlevSphere Support for Intel's Optane DC Persistent Memory (PMEM) (67645). Please note the recommended version to use is vSphere is 6.7u3.
If customers are using this technology in App-Direct Mode, there is no explicit approval needed. VMware support this technology on certified hardware. You can find the list of certified hardwarehere.
If customers are using this technology in Memory-Mode, customer need to procure an RPQ approval from VMware.
- It is important to highlight that VMware is supporting the Intel Optane Persistent Memory in memory mode and committed to develop the use-cases and market in close collaboration with Intel
- As this technology is new and runs at slower speed than DDR memory, we want to educate the market and develop the right use-cases and expectation. Due to this reason, VMware wants to work closely with early customers and help them succeed
- To address the above requirement, VMware is leveraging the existing RPQ process for early customers, VMware representative need to file the RPQ for interested customers. VMware request specific information from the customer environment. You can find the detailed information about filing the customer RPQ for Intel Optane Persistent Memory-mode here
- It is important to note that RPQ process is only for early customers. Once we develop the early success stories and use-case, VMware has all the intent to remove the RPQ requirements and make this technology as generally supported.
Please note, VMware is committed to support Intel Optane Persistent Memory in both modes “App-Direct” and “Memory-mode”. If you have any question, please feel free to reach out to @Sudhanshu Jain
Sudhanshu (Suds) Jain
Product Management – Cloud Infrastructure
Office: 650.427.7672 | Mobile: 408.393.7668
Subscribe to: