NSX multiple VTEPs load balancing
From: Kevin Barrass <kbarrass@vmware.com>
Date: Mittwoch, 24. Februar 2016 10:31
To: Yves Fauser <yfauser@vmware.com>, David Pasek <dpasek@vmware.com>, Emanuele Mazza <emazza@vmware.com>, Dimitri Desmidt <ddesmidt@vmware.com>
Subject: Re: NSX Question
Hi Yves, David.
Short answer is yes VM’s on the same logical switch on a host with two VTEP’s will most likely be balanced across those two VTEPs. Longer answer below :)
When you configure load balance SRCID or SRC MAC. We map dvPorts VM’s are attached to by either dvPort ID or MAC address of VM to one of the dvUplinks on the dvSwitch.
We also statically map each VTEP vmkernel interface to a dvUplink on the dvSwitch. This results in an approximate even split of VM’s across both uplinks.
Each VM will then be encapsulated in VXLAN by the IOChain of the dvUplink the VM is mapped to, the SRC IP of that encapsulation will be the VTEP vmkernel IP address that is mapped to the same dvUplink.
The Local Control Plane (netcpa) will report up to the central control plane this VM dvPort (MAC address) to VTEP mapping.
If a dvUplink on the dvSwitch should fail, all VM’s that were mapped to that dvUplink and the associated VTEP vmkernel interface will be re-mapped to one of the remaining dvUplinks. Also the Local Control Plane agent will report this re-mapping up to the central control plane.
You can view this mapping on the ESXi dataplane from using either esxtop or esxcli as well as on the central control plane as below,:
ESXTOP
9:12:12am up 13 days 17:46, 492 worlds, 3 VMs, 4 vCPUs; CPU load average: 0.03, 0.03, 0.03
PORT-ID USED-BY TEAM-PNIC DNAME PKTTX/s MbTX/s PKTRX/s MbRX/s %DRPTX %DRPRX
33554433 Management n/a vSwitch0 0.00 0.00 0.00 0.00 0.00 0.00
33554434 vmnic0 - vSwitch0 76.29 0.19 53.41 0.06 0.00 0.00
33554435 Shadow of vmnic0 n/a vSwitch0 0.00 0.00 0.00 0.00 0.00 0.00
33554436 vmk0 vmnic0 vSwitch0 76.29 0.19 0.00 0.00 0.00 0.00
50331649 Management n/a DvsPortset-0 0.00 0.00 0.00 0.00 0.00 0.00
50331650 vmnic3 - DvsPortset-0 0.00 0.00 0.00 0.00 0.00 0.00
50331651 Shadow of vmnic3 n/a DvsPortset-0 0.00 0.00 0.00 0.00 0.00 0.00
50331652 vmnic2 - DvsPortset-0 0.00 0.00 0.00 0.00 0.00 0.00
50331653 Shadow of vmnic2 n/a DvsPortset-0 0.00 0.00 0.00 0.00 0.00 0.00
50331654 vmk1 vmnic3 DvsPortset-0 0.00 0.00 0.00 0.00 0.00 0.00
50331655 vdr-vdrPort vmnic3 DvsPortset-0 0.00 0.00 0.00 0.00 0.00 0.00
50331660 52305:Palo Alto Netw vmnic2 DvsPortset-0 0.00 0.00 0.00 0.00 0.00 0.00
50331661 37661:Dom-Ubuntu01.e vmnic3 DvsPortset-0 0.00 0.00 0.00 0.00 0.00 0.00
50331662 41267:Dom-Windows02. vmnic3 DvsPortset-0 0.00 0.00 0.00 0.00 0.00 0.00
67108865 Management n/a DvsPortset-1 0.00 0.00 0.00 0.00 0.00 0.00
67108866 vmnic1 - DvsPortset-1 0.00 0.00 129.70 0.25 0.00 0.00
67108867 Shadow of vmnic1 n/a DvsPortset-1 0.00 0.00 0.00 0.00 0.00 0.00
ESXCLI
To view VM to dvUplink mapping
~ # esxcli network vm list
World ID Name Num Ports Networks
-------- --------------------------- --------- ---------------
37661 Dom-Ubuntu01 1 dvportgroup-540
41267 Dom-Windows02 1 dvportgroup-585
52305 Palo_Alto_Networks_NGFW_(1) 1 dvportgroup-520
~ # esxcli network vm port list -w 37661
Port ID: 50331661
vSwitch: DSwitch-Res01
Portgroup: dvportgroup-540
DVPort ID: 222
MAC Address: 00:50:56:87:6f:a9
IP Address: 0.0.0.0
Team Uplink: vmnic3
Uplink Port ID: 50331650
Active Filters: dvfilter-generic-vmware-swsec, vmware-sfw, serviceinstance-1
To View VM to vmkernel VTEP mapping
~ # esxcli network vswitch dvs vmware vxlan network port list --vds-name=DSwitch-Res01 --vxlan-id=5007
Switch Port ID VDS Port ID VMKNIC ID
-------------- ----------- ---------
50331655 vdrPort 0
50331661 222 0
~ #
~ # esxcli network vswitch dvs vmware vxlan vmknic list --vds-name=DSwitch-Res01
Vmknic Name Switch Port ID VDS Port ID Endpoint ID VLAN ID IP Netmask IP Acquire Timeout Multicast Group Count Segment ID
----------- -------------- ----------- ----------- ------- ---------- ------------- ------------------ --------------------- ----------
vmk1 50331654 20 0 10 172.16.1.4 255.255.255.0 0 0 172.16.1.0
~ #
Central Control Plane
htb-1n-eng-dhcp10 # show control-cluster logical-switches mac-table 5007
VNI MAC VTEP-IP Connection-ID
5007 00:50:56:87:6f:a9 172.16.1.4 51
5007 00:50:56:87:92:b1 172.16.1.5 52
5007 00:50:56:87:6e:32 172.16.1.3 45
Please don’t hesitate to contact me if you have anymore questions.
Kind Regards
Kev
Kevin Barrass – VCDX#191
Senior NSX Solutions Architect
Network and Security Business Unit
+44 (0)7825 034393
From: Yves Fauser <yfauser@vmware.com>
Date: Wednesday, 24 February 2016 08:59
To: David Pasek <dpasek@vmware.com>, Emanuele Mazza <emazza@vmware.com>, Dimitri Desmidt <ddesmidt@vmware.com>, Kevin Barrass <kbarrass@vmware.com>
Subject: Re: NSX Question
{Adding Emanuele, Dimitri and Kev}
Hi David,
I must admit that I don’t know the logic of how VM traffic gets placed onto the different VTEPs in a setup where multiple VTEPs are deployed per ESXi Host.
So I can’t tell you if we pin whole logical switches or individual VMs to the different VTEPs.
I’m sure one of our colleagues I added knows this and will educate me and yourself on it ;-)
Cheers,
Yves
Yves Fauser
Senior Solutions Architect
Mobile: +49 172 254 7415
From: David Pasek <dpasek@vmware.com>
Date: Dienstag, 23. Februar 2016 12:17
To: Yves Fauser <yfauser@vmware.com>
Subject: NSX Question
Hi Yves.
I have a simple question but so far I have get several contradictory answers from different VMware’s NSX experts.
Let’s assume I have NSX with multiple VTEPs (2) per ESXi host.
Is there a chance that each VM connected to the same logical switch will be load balanced across these two VTEPs?
Of course, it depends on hash algorithm result, but let’s assume hash result is unique for each VM.
Thanks in advance.
—
David Pasek, Senior Technical Account Manager
Wednesday, April 20, 2016
VM samples and VMX core dump on a running VM
A virtual machine is composed of several processes or userworlds that run in the VMkernel. Combined, the processes collectively make up a group. The following is a summary of components of a virtual machine:
- Virtual Machine Executable (VMX) process - A process that runs in the VMkernel that is responsible for handling I/O to devices that are not critical to performance. The VMX is also responsible for communicating with user interfaces, snapshot managers, and remote console.
- Virtual Machine Monitor (VMM) process - A process that runs in the VMkernel that is responsible for virtualizing the guest OS instructions, and manages memory. The VMM passes storage and network I/O requests to the VMkernel, and passes all other requests to the VMX process. There is a VMM for each virtual CPU assigned to a virtual machine.
- Mouse Keyboard Screen (MKS) process - A process that is responsible for rendering the guest video and handling guest operating system user input.
To set vmsamples up on a running VM, use "vmdumper -l" to list world IDs of running VMs and then "vmdumper <worldid> samples_on" to turn it on for that VM. This will last until the VM is power cycled/powered off or until a samples_off command is run.
Turn VM sample on
#vmdumper <worldid>samples_on
VMM core dump ...
vmdumper <worldid> unsync
vmdumper <worldid> sync
VMX core dump ...
vmdumper <worldid> vmx
vmdumper <worldid> vmx_force
VMkernel core dump ...
You can collect the live dump without crashing the box using -
localcli --plugin-dir /usr/lib/vmware/esxcli/int/ debug livedump perform
Turn VM sample off
#vmdumper <worldid>samples_off
Refer https://wiki.eng.vmware.com/DebuggingEsx#Creating_a_Live_Crash_Dump_for_ESXi
***************************************
Additional info:
Interpreting virtual machine monitor and executable failures (1019471)
Tags:
esxi, vmkernel, debug, coredump
Tuesday, March 29, 2016
FCoE Notes
QLA HBA -
Host Connectivity
- On QLogic CNAs, set the Link Down Timeout to 60 seconds (the default is 30 seconds) in the Advanced HBA Parameters. This is necessary to ensure proper recovery or failover if a link fails or becomes unresponsive.
Switch Configuration
fka-adv-period
VFC down due to FIP keepalive misses
The VFC goes down due to FIP keepalive misses.
Possible Cause
When FIP keepalives (FKA) are missed for a period of approximately 22 seconds, this means that approximately three FKAs are not continuously received from the host. Missed FKAs can occur for many reasons, including congestion or link issues.
FKA timeout : 2.5 * FKA_adv_period.
The FKA_adv_period is exchanged and agreed upon with the host as in the FIP advertisement when responding to a solicitation.
Observe the output from the following commands to confirm FKA misses: - show platform software fcoe_mgr info interface vfc <id>
- show platform software fcoe_mgr event-history errors
- show platform software fcoe_mgr event-history lock
- show platform software fcoe_mgr event-history msgs
- show platform fwm info pif ethernet <bound-ethernet-interface-id>
- Solution
Sometimes when congestion is relieved, the VFC comes back up. If the symptom persists, then additional analysis is required. The possible considerations are:
- The host stopped sending the FKA.
- The switch dropped the FKA that was received.
-
Saturday, March 26, 2016
VMtools - parameters
/v /qb-! REINSTALLMODE=vomus ADDLOCAL=All REMOVE=Hgfs,WYSE,Audio,BootCamp,Unity,VShield REBOOT=ReallySuppress
/v /qb-! REINSTALLMODE=vomus ADDLOCAL=All REBOOT=ReallySuppress
/S /v "/qn /l*v ""%TEMP%\vmtools-inst.log"" REBOOT=ReallySuppress ADDLOCAL=ALL REMOVE=Hgfs,WYSE,Audio,BootCamp,Unity,FileIntrospection,NetworkIntrospection"
/S /v "/qn /l*v ""%TEMP%\vmtools-inst.log"" REBOOT=ReallySuppress ADDLOCAL=ALL REMOVE=Hgfs,WYSE,Audio,BootCamp,Unity"
/v /qb-! REINSTALLMODE=vomus ADDLOCAL=All REBOOT=ReallySuppress
/S /v "/qn /l*v ""%TEMP%\vmtools-inst.log"" REBOOT=ReallySuppress ADDLOCAL=ALL REMOVE=Hgfs,WYSE,Audio,BootCamp,Unity,FileIntrospection,NetworkIntrospection"
/S /v "/qn /l*v ""%TEMP%\vmtools-inst.log"" REBOOT=ReallySuppress ADDLOCAL=ALL REMOVE=Hgfs,WYSE,Audio,BootCamp,Unity"
Friday, March 18, 2016
What's new in PowerCLI 6.3 R1
PowerCLI 6.3 R1 introduces the following new features and improvements:
Get-VM is now faster than ever!
The Get-VM Cmdlet has been optimized and refactored to ensure maximum speed when returning larger numbers of virtual machine information. This was a request which we heard time and time again, when you start working in larger environments with thousands of VMs the most used cmdlet is Get-VM so making this faster means this will increase the speed of reporting and automation for all scripts using Get-VM. Stay tuned for a future post where we will be showing some figures from our test environment but believe me, it’s fast!
New-ContentLibrary access
New in this release we have introduced a new cmdlet for working with Content Library items, the Get-ContentLibraryItem cmdlet will list all content library items from all content libraries available to the connection. This will give you details and set you up for deploying in our next new feature….
The New-VM Cmdlet has been updated to allow for the deployment of items located in a Content Library. Use the new –ContentLibrary parameter with a content library item to deploy these from local and subscribed library items, a quick sample of this can be seen below:
$CLItem = Get-ContentLibraryItem TTYLinux
New-VM -Name "NewCLItem" -ContentLibraryItem $CLItem -Datastore datastore1 -VMHost 10.160.74.38
New-VM -Name "NewCLItem" -ContentLibraryItem $CLItem -Datastore datastore1 -VMHost 10.160.74.38
Or even simpler….
Get-ContentLibraryItem -Name TTYLinux | New-VM -Datastore datastore1 -VMHost 10.160.74.38
ESXCLI is now easier to use
Another great feature which has been added has again come from our community and users who have told us what is hard about our current version, the Get-Esxcli cmdlet has now been updated with a –V2 parameter which supports specifying method arguments by name.
The original Get-ESXCLI cmdlet (without -v2) passes arguments by position and can cause scripts to not work when working with multiple ESXi versions or using scripts written against specific ESXi versions.
A simple example of using the previous version is as follows:
$esxcli = Get-ESXCLI -VMHost (Get-VMhost | Select -first 1)
$esxcli.network.diag.ping(2,$null,$null,“10.0.0.8”,$null,$null,$null,$null,$null,$null,$null,$null,$null)
Notice all the $nulls ? Now check out the V2 version:
$esxcli2 = Get-ESXCLI -VMHost (Get-VMhost | Select -first 1) -V2
$arguments = $esxcli2.network.diag.ping.CreateArgs()
$arguments.count = 2
$arguments.host = "10.0.0.8"
$esxcli2.network.diag.ping.Invoke($arguments)
Get-View, better than ever
For the more advanced users out there, those who constantly use the Get-View Cmdlet you will be pleased to know that a small but handy change has been made to the cmldet to enable it to auto-complete all available view objects in the Get-View –ViewType parameter, this will ease in the use of this cmdlet and enable even faster creation of scripts using this cmdlet.
Updated Support
As well as the great enhancements to the product listed above we have also updated the product to make sure it has now been fully tested and works with Windows 10 and PowerShell v5, this enables the latest versions and features of PowerShell to be used with PowerCLI.
PowerCLI has also been updated to now support vCloud Director 8.0 and vRealize Operations Manager 6.2 ensuring you can also work with the latest VMware products.
More Information and Download
For more information on changes made in vSphere PowerCLI 6.3 Release 1, including improvements, security enhancements, and deprecated features, see the vSphere PowerCLI Change Log. For more information on specific product features, see the VMware vSphere PowerCLI 6.3 Release 1 User’s Guide. For more information on specific cmdlets, see the VMware vSphere PowerCLI 6.3 Release 1 Cmdlet Reference.
You can find the PowerCLI 6.3 Release 1 download HERE. Get it today!
Subscribe to:
Posts (Atom)